Fall prevention · Roof and building site
Lifeline Installation and Safety Net Fitting
Lifeline installation gives a building permanent points to which people working on the roof or the facade can attach themselves. We install anchor points, horizontal lines and building-site edge safety nets, usually at heights that can only be reached by rope.
The products we use are manufactured to EN 795. We choose them according to the load-bearing structure of the building, the number of people who will use the line and how often the work is done.

EN 795 Anchor Types: From Point to Rail
- AFixed point
- A single anchor permanently fixed to concrete or steel. It is the starting point for facade descents.
- BPortable
- A temporary anchor installed and removed for the duration of the job; for one-off jobs on roofs with no permanent point.
- CFlexible horizontal line
- A steel cable stretched between two ends. The user stays attached along the line as they walk; intermediate supports are used at corners.
- DRigid rail
- A fixed rail with a trolley that slides along it instead of a cable; preferred under ceilings and eaves.
- ECounterweighted
- An anchor that stays in place under its own weight on flat roofs that cannot be drilled.
Roof Lifeline: Installation and Use
In buildings where facade lighting maintenance or glazing work is done regularly, permanent anchor points remove the need to set up a temporary anchor for every maintenance visit.
- 1
Identifying the structure
The slab thickness, parapet and steel members are inspected, and the place where the anchor will hold is determined.
- 2
Route
The line is laid out well back from the edge, starting at the roof access and going round the corners.
- 3
Anchors
Fixed with chemical or mechanical anchors, or with clamps; the waterproofing is renewed where it was drilled.
- 4
Tensioning
The cable is tensioned, with its tensioner and energy absorber, up to the manufacturer’s value.
- 5
Label
The number of users per line, the installation date and the date of the next inspection are recorded.
What We Often Hear About Lifelines
How often should a lifeline be inspected?
At the interval given in the manufacturer’s instructions for use; this is usually an inspection once a year by a competent person. A line that has arrested a fall is not used again until it has been inspected and approved.
How many people can attach to the same line?
As many users as are written on the line’s label and in the manufacturer’s documents. This number is determined by the length of the line, the spacing of the intermediate supports and the type of energy absorber; before choosing the product, we ask how many people will use the line and for what kind of work.
Can you renew an existing old line?
We can remove lines that have no documentation, are rusted or are damaged and install a new one in their place. If the old anchor points are to be reused, we first look at the condition of the structural element they are attached to.
Safety Net Installation: Floor Edge, Openings and Facade
- S
A horizontal net tensioned by rope at its edges; under atriums and large openings.
- T
A horizontal net lying on brackets; it catches a person or material falling from the floor edge.
- U
A net attached to a vertical frame; it acts as a guardrail at the floor edge.
- V
A vertical net hung from gallows-type posts; it is moved up floor by floor as the structure rises.
For as long as the net is in place, its connections are inspected regularly. A net that has caught a person or heavy material is not used again until it has been replaced.

Handover File: The Line’s Identity Card
When the installation is finished, we leave the management a file that explains where the line is and how to use it. Whoever carries out the later inspections, they start from this file.
- A roof plan marking the line and the anchor points
- The manufacturers’ documents and instructions for use for the products
- Installation photos and a list of the anchors and chemicals used
- The number of users and the inspection schedule for each line
- A record form to be filled in at later inspections